People arrive at this question three ways: from the units on their meter, from the rupees on their bill, or from the number of air conditioners they want to keep running. All three are the same question, and all three come back to one piece of arithmetic. This page shows the arithmetic, then answers each version of the question with prices taken from our daily rate feed rather than typed in once and left to rot.

The one calculation everything rests on

A solar system is sized to your consumption, not your house. The formula:

System size (kW) = monthly units ÷ (30 × peak sun hours × 0.8)

Two assumptions sit inside it, and you should know both:

  • Peak sun hours: 4.2. Not daylight hours — the equivalent hours of full-strength sun. Most of Pakistan averages between 4 and 5.5 across the year. 4.2 is deliberately conservative, so the system is not undersized in December.
  • System efficiency: 0.8. Panels never deliver nameplate output. Inverter losses, heat, dust and cable resistance take roughly a fifth. Dust matters more here than in most markets.

That works out to about 100 units per month for every 1 kW installed. If you remember one number from this page, remember that one — you can size any system in your head with it.

If you know your monthly units

Look at the units consumed line on your bill, not the rupees. Average the last twelve months if you can; summer and winter differ sharply in Pakistan and sizing off a July bill alone will oversize you.

Units per monthSystem size550W panelsRoof areaEstimated cost today
200 units2 kW4~11 m²Rs 144,000
300 units3 kW6~16 m²Rs 216,000
500 units5 kW10~26 m²Rs 360,000
700 units6.9 kW13~34 m²Rs 497,000
1,000 units9.9 kW18~47 m²Rs 713,000

Costed at Rs 41.00/watt, the median in-stock panel rate in our feed as of 18 November 2026, plus Rs 15,000/kW on-grid inverter and Rs 16,000/kW for structure, wiring and labour. Real quotes vary by roof and installer.

Roof area assumes a 550W panel takes about 2.6 m² including walkway gaps. A flat roof with good orientation needs less; a shaded or awkward roof needs more.

If you only know your bill

Divide the bill by your per-unit tariff to get units, then use the table above. The table below does it at Rs 55 per unit, which is in the range most domestic consumers on higher slabs pay — but tariffs are slab-based and change, so check your own bill and adjust. At a lower tariff the same bill means more units and a bigger system.

Monthly billRoughly this many unitsSystem size550W panelsEstimated cost today
Rs 10,000182 units1.8 kW4Rs 130,000
Rs 20,000364 units3.6 kW7Rs 259,000
Rs 30,000545 units5.4 kW10Rs 389,000
Rs 50,000909 units9 kW17Rs 648,000
Rs 80,0001,455 units14.4 kW27Rs 1,037,000

Costed at Rs 41.00/watt, the median in-stock panel rate in our feed as of 18 November 2026, plus Rs 15,000/kW on-grid inverter and Rs 16,000/kW for structure, wiring and labour. Real quotes vary by roof and installer.

If you are sizing around air conditioners

This is the most common way the question gets asked in Pakistan, and the most commonly got wrong. A 1.5-ton inverter AC draws roughly 950W while running — not its 1,800W startup figure, and not the 1.5-ton rating. Inverter units modulate, so average draw over a hot afternoon is well below peak.

The trap is sizing for the ACs alone and forgetting the fridge, fans, lights, pumps and everything else. The right-hand column is the one most households actually need.

Air conditioners (1.5-ton inverter)Typical running loadACs onlyACs plus the rest of the houseEstimated cost, larger size
1 × 1.5-ton~950 W3 kW4 kWRs 288,000
2 × 1.5-ton~1,900 W5 kW6 kWRs 432,000
3 × 1.5-ton~2,850 W7 kW9 kWRs 648,000

Costed at Rs 41.00/watt, the median in-stock panel rate in our feed as of 18 November 2026, plus Rs 15,000/kW on-grid inverter and Rs 16,000/kW for structure, wiring and labour. Real quotes vary by roof and installer.

Running ACs after sunset is a different problem entirely — that needs batteries, not more panels, and roughly doubles the cost. An on-grid system covers daytime cooling and exports the surplus.

What changes the answer

  • Net metering. On-grid with net metering lets daytime surplus offset evening consumption, so you can size to annual units rather than to your peak hour. Without it, anything you generate and do not use is wasted.
  • Roof space and orientation. South-facing is best in Pakistan. East or west costs you roughly 10–15%. If the roof cannot hold the panels the sizing needs, the roof wins.
  • Shade. One shaded panel can drag down a whole string. A water tank or a neighbour’s wall matters more than most buyers expect.
  • Growth. If you are likely to add an AC or an EV charger, size up now. Adding capacity later means a second inverter or replacing the first.
  • Your DISCO. Net metering is filed with LESCO, MEPCO, FESCO, GEPCO, IESCO, PESCO, QESCO, HESCO or SEPCO — and K-Electric runs a separate process.

A worked example

A household in Lahore averaging 640 units a month across the year:

  1. 640 ÷ (30 × 4.2 × 0.8) = 640 ÷ 100.8 = 6.3 kW
  2. At 550W per panel, that is 12 panels, needing about 31 m² of clear roof
  3. They run two ACs, so the AC table also points at 6 kW — the two methods agree, which is the check you want
  4. They plan to add a third AC next year, so they install 8 kW and keep the headroom

When the two methods disagree, trust the units. Appliance maths tells you what the house draws; the meter tells you what it actually used.

Price it properly

The figures above are a planning estimate at today’s median panel rate. For a quote-by-quote comparison with your chosen brand and inverter type, use the solar system cost calculator, which breaks out panels, inverter, structure, wiring and labour separately and shows a realistic range.

Today’s per-watt rates by brand are on the daily rate tracker. Before you accept any quote, read how to check an installer is licensed.

Frequently Asked Questions

How many units does 1 kW of solar produce in Pakistan?
About 100 units a month, or 3 to 4 units a day, using 4.2 peak sun hours and 80% system efficiency. Summer runs higher and December lower; the annual average is what matters for sizing.
Should I size for my summer bill or my yearly average?
The yearly average, if you have net metering — surplus generated in mild months offsets the summer peak. Size for the summer peak only if you have no net metering and no battery, in which case you are deliberately overbuilding for three months of the year.
Can a solar system run an AC at night?
Not without batteries. Panels generate nothing after sunset. A hybrid system with storage can, but the battery bank typically costs as much again as the rest of the system, so most households run cooling on solar by day and on the grid at night.
Is it better to oversize the system?
Modestly, yes — panels degrade slowly, dust reduces output, and households add load over time. Going far beyond your consumption is poor value, though, because net metering buyback under the NEPRA Prosumer Regulations 2026 pays less than the retail tariff you avoid by self-consuming.

Sources & references

Where this page states a rule, a tariff or a registration requirement, it comes from the documents below. Links go to the document itself, not a homepage. Prices on this page come from our own daily rate feed, not from these sources.

  • NEPRA (Prosumer) Regulations, 2026 — notified 6 August 2026. Sets the framework that replaced straight net metering with net billing. Under it, a prosumer facility of 25 kW or below does not need concurrence from the Authority.
  • NEPRA net-metering licences — the register of issued distributed-generation and net-metering licences.
  • Checklist for enlistment of installers under the AEDB (Certification) Regulations, 2021 — the actual requirements an installer must meet. Note that AEDB was dissolved and merged into PPIB in July 2023, so enlistment is handled by PPIB, even though the regulations still carry the AEDB name.
  • Your distribution company — LESCO, MEPCO, FESCO, GEPCO, IESCO, PESCO, QESCO, HESCO, SEPCO or K-Electric — for the tariff that applies to your area and the net-metering application itself. K-Electric runs its own process, separate from the DISCOs.

Regulatory links last checked 4 October 2026. Rules change; confirm current figures with the authority or a licensed installer before you commit money.

Abubaker Jalil
Written by

Abubaker Jalil

Abubaker Jalil is an electrical engineer and a graduate of the University of Engineering and Technology (UET) Peshawar. He tracks panel, inverter and battery prices across Pakistan's wholesale solar markets and writes the buying guides on this site. If a dealer has quoted you a figure that does not match what you see here, write to info@solarpricepakistan.com.pk and it gets checked.

Facebook
WhatsApp